  te90 90w single output external power test & measurement/industrial series www.slpower.com te90 rev 2.1 25-apr-16 1 features ? meets doe efficiency level vi requirements ? no load input power ? average efficiency ? up to 90w of ac-dc power ? universal input 90-264vac input range ? ip22 rated enclosure ? meets ?heavy industrial? levels of en61000 emc requirements ? meets en55011/cispr11, fcc part 15.109 class b conducted & radiated emissions, with 6db margin ? approved to en/iec/ul60950-1, 2 nd edition, am. 2 ? e-cap life of >7 years ? 3 year warranty ? rohs/reach compliant description a high performance ac to dc external power supply family designed for test & measurement and industrial applications. fully compliant with efficiency level vi requirements per u.s. dept. of energy, and also compliant to the heavy industrial levels of various en61000-4-x standards for emc. the te90 series models also meet class b conducted and radiated emi per fcc part 15, en55022, cispr22, with margin. designed to allow easy integration with test and measurement equipment and other industrial applications. model selection model output output ripple & line load output cable input number volts current power noise 1 regulation regulation & connector configuration te90a1251f01 12.0v 7.50a 90w 120mv pk-pk 1% 5% 6 pin molex type 2 class i desktop, iec60320 c14 receptacle te90a1503f01 15.0v 6.00a 90w 150mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive te90a1803f01 18.0v 5.00a 90w 180mv pk-pk 1% 5% te90a2403f01 24.0v 3.75a 90w 240mv pk-pk 1% 5% TE90A1251N01 12.0v 7.50a 90w 120mv pk-pk 1% 5% 6 pin molex type 2 class ii desktop, iec60320 c8 receptacle te90a1503n01 15.0v 6.00a 90w 150mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive te90a1803n01 18.0v 5.00a 90w 180mv pk-pk 1% 5% te90a2403n01 24.0v 3.75a 90w 240mv pk-pk 1% 5% te90a1251q01 12.0v 7.50a 90w 120mv pk-pk 1% 5% 6 pin molex type 2 class ii desktop, iec60320 c18 receptacle te90a1503q01 15.0v 6.00a 90w 150mv pk-pk 1% 5% 2.5 x 5.5 x 9.5mm straight barrel type, center positive te90a1803q01 18.0v 5.00a 90w 180mv pk-pk 1% 5% te90a2403q01 24.0v 3.75a 90w 240mv pk-pk 1% 5% notes: 1 . m e a s u r e d a t t h e o u t p u t c o n n e c t o r , w i t h n o i s e p r o b e d i r e c t l y a c r o s s o u t p u t a n d l o a d , t e r m i n a t e d w i t h 0 . 1 f c e r a m i c a n d 4 7 f l o w e s r c a p a c i t o r s . 2. molex p/n 39-01-2060 or equivalent. see outline drawing for pinout information. 3. for input class i models: for ac gnd connected to output common (-), insert a ?b? in the part number where the ?a? is located (te90b1251f01). 4. all specifications are typical at nominal input, full load, at 25 c ambient unless noted.
te90 90w single output external power test & measurement/industrial series www.slpower.com te90 rev 2.1 25-apr-16 2 general specifications ac input 100-240vac, 10%, 47-63hz, 1 ? turn on time less than 1 sec @115vac, full load input current 115vac: 1.2a, 230vac: 0.6a hold-up time 20ms min., at full load, 100vac input inrush current 264vac, cold start: will not exceed 60a overtemperature protection will shutdown upon an over-temperature condition, auto-recovery. input fuses f1, f2: 5a, 250vac fuses (line & neutral lines) provided on all models overload protection 130 to 180% of rating, hiccup mode earth leakage current i n p u t - g n d : < 5 0 0 a @ 2 6 4 v a c , 6 0 h z , n c output-gnd: <4ma@264vac, 60hz, nc short circuit protection hiccup mode, auto recovery. efficiency meets us doe efficiency level vi average efficiency levels overvoltage protection 130 to 150% of output voltage (max. 60v on 48v model), hiccup mode output power 90w continuous ? see models chart for specific voltage model ratings. isolation input-output: 4000vac input-ground: 1500vac output-ground: 1500vac no load input power <0.210w per doe efficiency level vi requirements safety standards en/csa/ul/iec 60950-1, 2nd edition, am 2 ripple and noise see models chart on pg 1. operating temperature -20c to +70c. derate above 40 c. output voltage see models chart on pg 1. case temperature case temperatures are within regulatory guidelines. care should be taken to avoid prolonged contact with skin or other heat sensitive surfaces. transient response 500 s response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, ? i/ ? t< 0.2a/ s. max. voltage deviation is +/-3.5%. temperature derating see derating chart e-cap life >7 year life based on calculations at 115vac/60hz & 230vac/50hz, ambient 25c at 24 hrs per day, 365 days/year, 6 power up cycles per day. (80% load on 12v model) mtbf >500,000 hours, full load, 110 & 220vac input, 25 c amb., per telcordia 332 issue 6. weight 600g storage temperature -40c to +85c safety drop test 1.4m from table top to wooden platform, 6 faces. altitude operating: to 5000m (derate to tbd temp. above 3000m). non-operating: -500 to 40,000 ft. dimensions w: 2.58? x l: 5.9? x h: 1.34? w: 65.5mm x l: 150.5mm x h: 34mm relative humidity 5% to 95%, non-condensing vibration operating: 0.003g/hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500hz. non-oper.: random waveform, 3 minutes per axis, 3 axes and sine waveform, vib. frequency/acceleration: 10-500hz/1g, sweep rate of 1 octave / minutes, vibration time of 10 sweeps / axes, 3 axes shock operating: half-sine, 20gpk, 10ms, 3 axes, 6 shocks total non-operating: half-sine waveform, impact acceleration of 100g, pulse duration of 6 ms, number of shocks: 3 for each of the three axis all specifications are typical at nominal input, full load, at 25 c ambient unless noted.
te90 90w single output external power test & measurement/industrial series www.slpower.com te90 rev 2.1 25-apr-16 3 emi/emc compliance conducted emissions: en55011/cispr22 class b, fcc part 15.107, class b: 6db margin typ, at 115 and 230vac radiated emissions: en55022/cispr22 class b, fcc part 15.109, class b: 3db margin typ, at 115 and 230vac common mode noise: high frequency (100khz-20mhz): <40ma pk-pk electro-static discharge (esd) immunity on power ports: en55024/iec61000-4-2, level 4: +/- 8kv contact, +/- 15kv air, criteria a radiated rf em fields susceptibility en55022/en61000-4-3, 10v/m, 80mhz-2.7ghz, 80% am at 1khz electrical fast transients (eft) /bursts: en55024/iec61000-4-4, level 4, +/- 4kv, 100khz rep rate, 40a, criteria a surges, line to line (diff mode) and line to gnd (cmn mode) en55024/iec61000-4-5, level 4, +/-2kv dm, +/-4kv cm, criteria a conducted disturbances induced by rf fields en55022/iec61000-4-6, 10vrms ? level 4, in ism and amateur radio bands between 0.15mhz and 80mhz, 80% am at 1khz rated power frequency magnetic fields en55024/iec1000-4-8, level 4: 30 a/m, 50/60 hz voltage interruptions, dips, sags & surges en55024/iecen61000-4-11: --100% dip for 10 ms, at 0, 45, 90, 135, 180, 225, 270 and 315 degrees; 20ms at 0 degrees. criteria a --100% dip for 5000ms (250/300 cycles), criteria b --60% dip for 100ms, criteria b --30% dip for 500ms, criteria a harmonic current emissions en55011/en61000-3-2, class a flicker test en61000-3-3 notes: performance criteria are based on en55024. according to the standards, performance criteria are defined as following: a ? normal performance during and after the test b ? temporary degradation, self-recoverable c ? temporary degradation, operator intervention required to recover the operation d ? permanent damage derating chart: 0 10 20 30 40 50 60 70 80 90 100 -20 -10 0 10 20 30 40 50 60 70 o u t p u t p o w e r - w w a t t s a m b i e n t t e m p e r a t u r e - ? c 12v-24v
te90 90w single output external power test & measurement/industrial series www.slpower.com te90 rev 2.1 25-apr-16 4 65.50.5 65.50.5 340.5 340.5 1 5 0 . 5 0 . 5 1 5 0 . 5 0 . 5 mechanical drawing: 15v through 24v models: 2.5 x 5.5 x 9.5mm 12v models: output connector: 6 pin molex 39-01-2060 barrel connector, center positive. or equiv. pins 1, 4 = (+), pins 3, 6 = (-), pins 2, 5 = nc notes: 1) all dimensions in mm. 2) the unit should not be covered or enclosed to protect against excessive case temperature rise. connector information standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (ault #3), center positive. (#51 for the 12v models). other standard options are listed below. the ?03? in the standard model number is replaced by the applicable digits below:
te90 90w single output external power test & measurement/industrial series www.slpower.com te90 rev 2.1 25-apr-16 5 efficiency level vi information: data sheet ? 2016 sl power electronics corp. the information and specifications contained herein are believed to be correct at the time of publication. however, sl power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. specifications are subject to change without notice. te90a series


▲Up To Search▲   

 
Price & Availability of TE90A1251N01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X